16-Channel High Throughput Octet® RH16
From IgG titer to epitope binning, the Octet® RH16 system offers label-free biomolecular interaction analysis with state-of-the-art high throughput platforms that facilitate the rapid characterization and development of biologics drug molecules.
High detection sensitivity, throughput, and 384-microwell plate compatibility of the Octet® RH16 system have also made it a favorite for small molecule library screening and analysis of large cross-competition binding campaigns. The Octet® RH16 instrument also supports additional automation for extending walk-away times and reducing operator input. Target ligands can be batch immobilized onto biosensors and returned to the biosensor tray for re-use in future experiments, thus extending the number of uses for each biosensor, preserving valuable ligand, and maximizing flexibility in experimental design.
Boost your research and commercialization goals by combining BLI and SPR at an attractive promotional price.
Arrange assay samples in 96- or 384-well plates depending on workflows and sample volumes
Supports larger sample and reagent capacities increasing walk-away times
The Octet® RH16 system utilizes Dip and Read technology where biosensors dip into samples housed in microplates. With no fluidics involved, Octet® systems have more uptime and lower operational costs
ELISAs are known for having variability in results, susceptibility to human error, and slow times-to-results. High throughput Octet® systems are designed to overcome those limitations. Convert your ELISA assay into an Octet® assay.
Read Application Note
The epitope binning process identifies and arranges antibody candidates that bind similar epitope regions to an antigen into bins. Octet® epitope binning assays rely on testing the sequential binding ability of two antibodies to an antigen. Assay speed, throughput, exceptional reproducibility, and dedicated software tools make Octet® platforms ideal for analyzing large antibody libraries.
Protein contaminants are a major hurdle to overcome during the production of biopharmaceuticals. The Octet® platform's rapid high throughput protein analysis combined with the anti-CHO HCP and Residual Protein A kits provide biologics developers with a fast and easy-to-use assay for contaminant testing.
Download Technical Note
Epitope binning through cross competition assays is a powerful tool in evaluating functional diversity in antibody clones.
Improve the overall drug discovery process to increase the success rate of preclinical candidates
Octet® GxP packages support the GMP compliant implementation, including 21 CFR Part 11 software, validation packages, and biosensor validation support...
Without Added Sample Purification Steps
Technologies, Key Considerations, and Applications
Technology
Bio-Layer Interferometry (BLI) based on fiber optic biosensors
Sample volume
40–80 μL/well (384-well tilted bottom microplate) and 180–220 μL/well (96-well microplate), nondestructive testing, easily recovered
Data presentation
Plots displaying kinetic binding, equation fits, and residuals of fits Tabulated kinetic data and data charts
Automation
Robot compatible microplate and biosensor tray loading
Orbital flow capacity
Static or 100–1500 rpm
Analysis temperature
Ambient + 4°C to 40°C, in 1°C increments
Association rate constant (ka)
101 to 107 M-1 s-1
Dissociation rate constant (kd)
10-6 to 10-1 s-1
Affinity constant (KD)
1 mM to 10 pM
Baseline noise (RMS)
≤ 4 pm (RMS)
Baseline drift
< 0.1 nm/hour
Quantitation range
8–16 biosensors: 0.05–300 μg/mL of hIgG at 1000 rpm**; 0.5–2000 μg/mL at 400 rpm
Quantitation precision
CV <10%
Weight
150 lb (68.2 Kg)
Dimensions (H x W x D)
30.1" H x 31.5" W x 31.5" D (77 cm H x 80 cm W x 80 cm D)
Sample type
Proteins, antibodies, peptides, serum containing media (up to 25%), DMSO containing buffers, virus-like particles, untreated cell culture supernatants and crude cell lysates
Sample plate
Standard, 96-well and 384-well, black, tilted bottom microplates
Molecular weight detection
>150 Da (8–16 biosensors)
Monitors up to 96 biosensors simultaneously, enabling label-free detection for protein quantitation and kinetic characterization at unmatched speed
Unmatched flexibility and versatility in protein analysis
The perfect balance between cost and throughput with given leeway
Grows with your biomolecule characterization needs
Affordably priced label-free analysis for individual researchers on any budget
The Octet® AS enables simultaneous and uniform reagent loading onto all 96 biosensors in a biosensor tray.
Get the Latest Updates, Trends and Developments on Label-free, Stress-Free Solutions for Drug Discovery, Biologics Development and Biomanufacturing.
We're offering an incredible deal - Bundle an Octet® BLI and SPR instrument and benefit from exceptional savings! This is your chance to bring the top two technologies for label-free biomolecular interaction analysis to your lab.
Please select your country so we can show you products that are available for you.
The content of our website is always available in English and partly in other languages. Choose your preferred language and we will show you the content in that language, if available.