This page does not exist in your selected language. Your preference was saved and you will be notified once a page can be viewed in your language.
This page is also available in your prefered language. Switch to that version.
Quickly find OEM and Diagnostic Membranes by using our search and filter tools.
Our Unisart® nitrocellulose membranes are specifically designed to be the ideal solid phase for all diagnostic lateral flow immunoassays. Every step in the Unisart® membrane manufacturing process has been optimized in order to obtain a reproducible 3D membrane structure with a clean and defect-free membrane surface. The homogenous structure of our membranes ensures a controlled and uniform lateral wicking of samples and reagents across the membrane which leads to improved accuracy and reproducibility of lateral flow test results.
Download the application note to learn more about the science behind the high quality of Sartorius Unisart®️ CN Membranes.
Reliable capillary speed, high protein binding, homogenous thickness and a smooth and defect-free membrane surface are essential to obtain high quality lateral flow test strips. The exceptionally high inter- and intra-lot consistency of our Unisart® membranes will help you to minimize the variability within lateral flow immunoassays and ensures accurate and precise results. Producing more consistent readouts improves test strip performance and reduces manufacturing costs.
In-depth know-how in nitrocellulose membrane manufacturing as well as relevant application expertise are driving us to continuously improve our state-of-the-art manufacturing equipment. As a technology leader, we guarantee reliable supply of high quality nitrocellulose membranes and also ensure availability of our Unisart® membranes on large scale.
We focus on quality in every step of our membrane manufacturing which is located in Göttingen, Germany. Our Unisart® membranes are developed, produced and distributed according to a Quality Management System that is certified in compliance with DIN/ISO 9001. All products must pass our precisely defined in-house tests and meet our stringent quality control standards throughout all manufacturing steps.
All Unisart® membrane products have a comprehensive and easy to read out labeling which allows convenient retrieval of all data compiled on materials used, production steps and QC tests. Quality assurance certificates guarantee full visual inspection and conformity to specifications for all Unisart® lateral flow membranes.
The nitrocellulose membrane is one of the most important components of a lateral flow rapid test and should be selected carefully. Especially the capillary speed of the membrane is very critical for lateral flow strip functionality as it affects sensitivity, specificity, response time and eventually costs of the assay. Each membrane type of our Unisart® nitrocellulose membrane family has a specific range of capillary speed. Our Unisart® CN 95 membrane is perfectly suited for high viscous samples and produces test strips with very short response times. Consequently Unisart® CN 95 is the membrane of choice when a quick response is desirable. In contrast, test strips with our Unisart® CN 180 DX membrane have the longest response time, but the assays will show the highest sensitivity. According to the application, reagents and manufacturing conditions our Unisart® CN 110, CN 140 and CN 150 membranes provide a different optimum for speed, specificity and sensitivity. Our wide selection of Unisart® membranes allows you to find the one that best meets the requirements of your diagnostic assay.
Sartorius is globally recognized for an expertise in biotherapeutics, including solutions for in vitro diagnostics kit (IVD) manufacturers. We can help you:Design a standardized sample preparation protocol before diagnosis with tailored lab instruments and consumables
Find Out More
Membrane Material
cellulose nitrate
Backing
100 µm polyester, clear
none
Thickness (µm)
240 - 270
185 - 215
120 - 160
225 - 255
240 - 280
Capillary speed down web, purified water (s/40mm)
65 - 115
90 - 130
90 - 150
95 - 155
90 - 180
135 - 175
Visual appearance
Wettability
Precise amount of anionic surfactant allows for fast wetting
Membrane wound with yellow interleaving protection paper between the membrane layers.
100 µm clear
no
yes
Background clearing
very fast
fast
Time–to-signal
medium
Quick response tests
best suitable
Sensitivity
good
very good
excellent
Viscous samples
Particle loaded samples
no, cards need to be selected carefully
suitable
Suitable for reel-to-reel manufacturing
CN 95
20
50
0
5 rolls
1UN95ER050020WSB
25
1UN95ER050025WSB
30
3
1UN95ER050030—B
100
1 roll
1UN95ER100020NT
1
1UN95ER100025KSB
1UN95ER100025NTB
28
1UN95ER100028NTB
1UN95ER100030—B
35
1UN95ER100035NTB
40
1UN95ER100040WS
70
1UN95ER100070WS
CN 110
1UN11ER100020NTB
1UN11ER100025NTB
1UN11ER100025NT
CN 140
200
0.25
2 sheets
1UN14AS25020001
1UN14AR050020—B
1UN14AR050025—B
1UN14AR100020NTB
1UN14AR100020WSB
1UN14AR100025NTB
1UN14AR100025WSB
1UN14AR100035NTB
1UN14AR100040NT
270
1UN14AR100270NT
1UN14ER050020—B
1UN14ER050025—B
1UN14ER050025WSB
17
1UN14ER100017NT
18
1UN14ER100018NTB
1UN14ER100020NT
1UN14ER100020NTB
1UN14ER100025NT
1UN14ER100025NTB
1UN14ER100028NTB
1UN14ER100030—B
1UN14ER100035NTB
1UN14ER100040WSB
1UN14ER100070
CN 150
1UN15LR050020NTB
1UN15LR050025NTB
1UN15LR100020NTB
1UN15LR100025NT
1UN15LR100025NTB
100 µm white
1UN15WR100025NTB
CN 180 DX
1DX18ER100020NTB
1DX18ER100025NTB
Customized dimensions of Unisart® nitrocellulose membranes are also available upon request.
If stored according to our storage recommendations, UniSart® Membranes have a shelf-life of 3 years after their manufacturing date. UniSart® Microarray Slides have a shelf-life of 1 year after their manufacturing date. The shelf-life is indicated on each Certificate of Analysis.
It is recommended to store UniSart® membranes at a constant temperature between 15 – 25°C and a relative humidity between 40 – 60 %. In any case, the membrane should be kept away from open fire, heat sources, light and chemical vapors of any kind.
It is recommended to keep the membrane rolls in their original packaging and keep it closed in a dedicated storage area. The membrane roll with paper separator is packed in a primary packaging (plastic pouch). The article in primary packaging is packed in a secondary packaging (cardboard box).
The paper separator has an important safety function. Therefore, it must be ensured that the paper separator is not removed from the membrane rolls before processing. The paper separator significantly reduces the decomposition rate of our UniSart® membranes. All UniSart® membranes are exclusively sold containing this paper separator.
When handling UniSart® membranes ensure sufficient ventilation and avoid direct skin contact to prevent contamination of the membrane. Furthermore, prolonged direct contact to any material that can release chemicals should be avoided. These substances might alter important membrane properties such as wettability.
Do not store more membrane than needed for your daily production in your working area.
Sartorius offers five different membrane types within the UniSart® CN Membranes portfolio with a broad range of different formats. Download the brochure.
Some of the products are available on the Sartorius eShop and can be ordered online. If your desired item is not included, please contact our team via unisart@sartorius.com.
Please select your country so we can show you products that are available for you.
The content of our website is always available in English and partly in other languages. Choose your preferred language and we will show you the content in that language, if available.
Shop Sartorius Products Now