This page does not exist in your selected language. Your preference was saved and you will be notified once a page can be viewed in your language.
This page is also available in your prefered language. Switch to that version.
The Easy Choice – Syringeless and Fast
Preparing samples by clarification is an essential first step for nearly all analytical techniques. Sample preparation by clarification is particularly important for techniques such as high-pressure liquid chromatography (HPLC). HPLC, however, presents some challenges today: It requires precision particle removal (from small volumes) that need to come through filters that do not add extractables or leachables to the mix that can complicate analysis. The process has to be fast and very easy. HPLC is hard enough - preparing samples for it should not be!
Fortunately, Sartorius’ legendary innovation has led to the development of a new, easy-to-use and straightforward filtration expressly tailored for modern HPLC needs. The manually operated Claristep® Syringeless Filtration System, consisting of a station and filter units, provides a smart and simple fix for the demanding HPLC process.
Request a Free Demo
Quickly find Sartorius syringeless filtration products using our search and filter tools
The Sartorius Claristep® Syringeless Filtration System can run up to eight samples in parallel and outperform syringe filters. This video demonstrates the preparation of samples from start to finish.
The Sartorius Claristep® Syringeless Filtration System makes light work of a tedious sample preparation task. This video provides a side-by-side comparison of a conventional procedure vs. the Claristep® system.
The Claristep® Station consists of a base, lid and exchangeable tray for easy and accurate positioning of sample vials and Claristep® Filter units. The patent-pending design features unique grooves in the station lid and matching guide ridges on Claristep® Filter units to enable intuitively correct alignment and convenient handling.
Buy Claristep® Station Now
Major benefits of Claristep® Filter units include extremely short contact times between samples and corresponding filters and caps. This ensures optimal, contamination-free results. Filtered liquids are collected in your choice of 12 × 32 mm outer diameter vials, based on the analytical method to be performed.
Buy Filter Units Now
Get answers to any questions you have about Sartorius syringeless filters.
Simply place the filters on your vials, gently close the station and press on the station lid to filter
A syringeless solution will minimize hand stress and help reduce time, effort and.
The manually operated Claristep® Filtration System (consisting of a station and filter units) offers a novel way for clarifying samples prior to analysis.
This system offers fast clarification of small volumes without the addition leachables or extractables to the original sample, making it indispensable for achieving the best analytical results.
Yes. We recommend processing Claristep® Filter units with the Claristep® Station. Claristep® Station is comprised of a station and one exchangeable Claristep® Tray. The Claristep® Tray can be purchased separately to order the number of trays needed for sample clarification.
Yes. In addition to Claristep® Filter units and Claristep® Station, you will need 12 + 32 mm sample vials and caps. Sartorius does not sell 12 + 32 mm vials, which are available in many configurations (clear glass, brown glass, PP, other plastics, with/without insert, crimp-top, screw-cap, snap-cap, etc.). They are offered by many companies and distributors.
Yes. In principle it is possible to manually use one Claristep® Filter unit for clarification of one sample. However, consider that clarification has been optimized for use with Claristep® Station. Without this station and tray, Sartorius cannot guarantee optimal clarification results. The tray is optimized for holding 12 + 32 mm vials. More important, the Claristep® Filter units positioned on top of the vials are not in direct contact with these vials. As a result, if glass vials are used, they are not exposed directly to the pressure applied by the station lid to close Claristep® Filter units. Therefore, this minimizes the risk of glass breakage.
Currently no. Claristep® Filter units will be launched with a choice of 0.2 μm and 0.45 μm pore size regenerated cellulose (RC) membranes. RC is suitable for nearly any preparation steps requiring filtration of aqueous and solvent samples. The only limitations are pH values of less than 3. Only strong acids cannot be processed using RC membranes
The effective filtration area is 0.74 cm2. We have optimized the ratio of filtration area to sample volume and therefore offer high filtration capacity, while minimizing the hold-up volume.
Ergonomic and Efficient Filtration for Food Analytics: Preparation of particle-containing and viscous food samples with the Claristep® system
Claristep® Filtration Assembly: A Novel Sample Preparation Method Suitable for the Analytics of Phthalates in Solid Environmental Samples
Impact of the Claristep® Filtration System on Recovery and Adsorption of Various Therapeutic Proteins at Low Sample Volumes
Please enter your email address and download the application note.
Please select your country so we can show you products that are available for you.
The content of our website is always available in English and partly in other languages. Choose your preferred language and we will show you the content in that language, if available.